Loading...
HomeMy WebLinkAboutROUGH CARPENTRY_Rev_0Five Sullivan Brothers CC Kitchen Plmb Improvements 06 10 00 City of Waterloo ROUGH CARPENTRY INVISION #16021 1 of 4 SECTION 06 10 00 ROUGH CARPENTRY PART 1 GENERAL 1.01 SECTION INCLUDES A. Preservative treated wood materials. B. Fire retardant treated wood materials. C. Concealed wood blocking, nailers, and supports. 1.02 RELATED REQUIREMENTS A. Section 09 21 16 - Gypsum Board Assemblies: Gypsum-based sheathing. 1.03 REFERENCE STANDARDS A. ASTM A153/A153M - Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware; 2016a. B. ASTM D2898 - Standard Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing; 2010 (Reapproved 2017). C. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials; 2018. D. AWPA U1 - Use Category System: User Specification for Treated Wood; 2017. E. PS 1 - Structural Plywood; 2009. F. PS 20 - American Softwood Lumber Standard; 2015. 1.04 DELIVERY, STORAGE, AND HANDLING A. General: Cover wood products to protect against moisture. Support stacked products to prevent deformation and to allow air circulation. B. Fire Retardant Treated Wood: Prevent exposure to precipitation during shipping, storage, or installation. PART 2 PRODUCTS 2.01 GENERAL REQUIREMENTS A. Dimension Lumber: Comply with PS 20 and requirements of specified grading agencies. 1. If no species is specified, provide any species graded by the agency specified; if no grading agency is specified, provide lumber graded by any grading agency meeting the specified requirements. 2. Grading Agency: Any grading agency whose rules are approved by the Board of Review, American Lumber Standard Committee (www.alsc.org) and who provides grading service for the species and grade specified; provide lumber stamped with grade mark unless otherwise indicated. 3. Lumber of other species or grades is acceptable provided structural and appearance characteristics are equivalent to or better than products specified. B. Lumber fabricated from old growth timber is not permitted. C. Engineered wood products containing added urea-formaldehyde are not permitted. 2.02 DIMENSION LUMBER FOR CONCEALED APPLICATIONS A. Sizes: Nominal sizes as indicated on drawings, S4S. B. Moisture Content: S-dry or MC19. C. Fire-retardant treated. D. Miscellaneous Framing, Blocking, Nailers, Grounds, and Furring: 1. Lumber: S4S, No. 1 or Construction Grade. 2. Boards: Standard or No. 3. 2.03 CONSTRUCTION PANELS A. Wall Sheathing: Plywood, PS 1, Grade C-D, Exposure I. B. Communications and Electrical Room Mounting Boards: PS 1 A-D plywood, or medium density fiberboard; 3/4 inch thick; flame spread index of 25 or less, smoke developed index of 450 or less, when tested in accordance with ASTM E84. C. Concealed Backing for wall-mounted items- Provide backing as required for loading from one of the following: 1. Dimension Lumber: As noted above. 2. Plywood: As noted below. Five Sullivan Brothers CC Kitchen Plmb Improvements 06 10 00 City of Waterloo ROUGH CARPENTRY INVISION #16021 2 of 4 3. All wood backing to be fire-rated. 4. Sheet metal on top of studs, beneath gypsum board finish: 12-inch wide strips of 18 gage galvanized sheet metal on top of studs, beneath gypsum board finish.. 5. Contractor's option: Proprietary fire-resistance-treated blocking and bracing in width indicated or required for loading; contractor to confirm coordination with final imposed loading at all locations used. ClarkDietrich Building Systems LLC Danback Fire-Treated Wood Backing Plate. D. Plywood Applications: 1. Plywood Concealed From View But Located Within Exterior Enclosure: PS 1, C-C Plugged or better, Exterior grade. 2. Plywood Exposed to View But Not Exposed to Weather: PS 1, A-D, or better. 3. Other Locations: PS 1, C-D Plugged or better. 2.04 ACCESSORIES A. Fasteners and Anchors: 1. Metal and Finish: Hot-dipped galvanized steel complying with ASTM A153/A153M for high humidity and preservative-treated wood locations, unfinished steel elsewhere. 2. Drywall Screws: Bugle head, hardened steel, power driven type, length three times thickness of sheathing. 3. Anchors: Expansion shield and lag bolt type for anchorage to solid masonry or concrete. 2.05 FACTORY WOOD TREATMENT A. Treated Lumber and Plywood: Comply with requirements of AWPA U1 - Use Category System for wood treatments determined by use categories, expected service conditions, and specific applications. 1. Fire-Retardant Treated Wood: Mark each piece of wood with producer's stamp indicating compliance with specified requirements. B. Fire Retardant Treatment: 1. Exterior Type: AWPA U1, Category UCFB, Commodity Specification H, chemically treated and pressure impregnated; capable of providing a maximum flame spread index of 25 when tested in accordance with ASTM E84, with no evidence of significant combustion when test is extended for an additional 20 minutes both before and after accelerated weathering test performed in accordance with ASTM D2898. a. Kiln dry wood after treatment to a maximum moisture content of 19 percent for lumber and 15 percent for plywood. b. Do not use treated wood in direct contact with the ground. 2. Interior Type A: AWPA U1, Use Category UCFA, Commodity Specification H, low temperature (low hygroscopic) type, chemically treated and pressure impregnated; capable of providing a maximum flame spread index of 25 when tested in accordance with ASTM E84, with no evidence of significant combustion when test is extended for an additional 20 minutes. a. Kiln dry wood after treatment to a maximum moisture content of 19 percent for lumber and 15 percent for plywood. b. Treat rough carpentry items as indicated . c. Do not use treated wood in applications exposed to weather or where the wood may become wet. PART 3 EXECUTION 3.01 PREPARATION A. Coordinate installation of rough carpentry members specified in other sections. 3.02 INSTALLATION - GENERAL A. Select material sizes to minimize waste. B. Reuse scrap to the greatest extent possible; clearly separate scrap for use on site as accessory components, including: shims, bracing, and blocking. C. Where treated wood is used on interior, provide temporary ventilation during and immediately after installation sufficient to remove indoor air contaminants. 3.03 BLOCKING, NAILERS, AND SUPPORTS A. Provide framing and blocking members as indicated or as required to support finishes, fixtures, specialty items, and trim. B. In metal stud walls, provide continuous blocking around door and window openings for anchorage of frames, securely attached to stud framing. Five Sullivan Brothers CC Kitchen Plmb Improvements 06 10 00 City of Waterloo ROUGH CARPENTRY INVISION #16021 3 of 4 C. In walls, provide blocking attached to studs as backing and support for wall-mounted items, unless item can be securely fastened to two or more studs or other method of support is explicitly indicated. D. Where ceiling-mounting is indicated, provide blocking and supplementary supports above ceiling, unless other method of support is explicitly indicated. E. Provide the following specific non-structural framing and blocking: 1. Cabinets and shelf supports. 2. Wall brackets. 3. Grab bars. 4. Towel and bath accessories. 5. Wall-mounted door stops. 6. Chalkboards, tack boards and marker boards. 7. Wall paneling and trim. 8. Wall-Protection items, including corner guards. 9. Owner-provided wall-mounted equipment, whether owner-installed or contractor-installed. 3.04 INSTALLATION OF CONSTRUCTION PANELS A. Communications and Electrical Room Mounting Boards: Secure with screws to studs with edges over firm bearing; space fasteners at maximum 24 inches on center on all edges and into studs in field of board. 1. At fire-rated walls, install board over wall board indicated as part of the fire-rated assembly. 2. Where boards are indicated as full floor-to-ceiling height, install with long edge of board parallel to studs. 3. Install adjacent boards without gaps. 3.05 TOLERANCES A. Framing Members: 1/4 inch from true position, maximum. B. Variation from Plane (Other than Floors): 1/4 inch in 10 feet maximum, and 1/4 inch in 30 feet maximum. 3.06 CLEANING A. Waste Disposal: 1. Comply with applicable regulations. 2. Do not burn scrap on project site. 3. Do not burn scraps that have been pressure treated. 4. Do not send materials treated with pentachlorophenol, CCA, or ACA to co-generation facilities or “waste-to-energy” facilities. B. Do not leave any wood, shavings, sawdust, etc. on the ground or buried in fill. C. Prevent sawdust and wood shavings from entering the storm drainage system. END OF SECTION