HomeMy WebLinkAboutFUSION BAR-1915 BOURLAND AVEINVOICE DATE
DUE DATE
INVOICE #
TOTAL DUE
10/12/2026
11/16/2026
2027-00000179
$80.00
Customer #: 23343
FUSION BAR
1915 BOURLAND
WATERLOO, IA 50702
Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL FIRE INSPECTION - 1915 BOURLAND AVE-
10/07/26
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
23343
BILLING DATE
DUE DATE
INVOICE #
CHARGES
10/12/2026
11/16/2026
2027-00000179
$80.00
Less Prepayment
Total Due —�
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Fusion Bar - 1915 Bourland AVE, BLDG 1915 Bourland Ave, Waterloo IA 50702
INSPECTION DETAILS
Inspection Date
1010712026
Inspection Type
Annual Inspection (1Yr)
a33q-3
Lead Inspector Shit: Station
BRAD BALDWIN NIA NIA
Other Inspectors
N/A
425 E. 3rd Street
Inspection Number
4.) 9b 19059
Unit
NIA
SUMMARY OF INSPECTION
0 33
Passed codes
NEXT STEPS
05
Failed codes
37
NIA codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 10/0812026 @ 08:41
Fire extinguishers due annually serviced November 2026.
BRAD BALDWIN - 1010812026 @ 08:38
Exterior Christmas lighting approved for temporary use (90 days) only. Remove lighting after 90 days.
Reinspection Date
11/05/2026
BRAD BALDWIN - 10/0812026 @ 08:37
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 10/08/2026 @ 08:37
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 10/08/2026 @ 08:37
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224
BRAD BALDWIN - 10/08/2026 @ 08:37
• $80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Cecilia 2025 Date: BRAD BALDWIN 1010812026
GENEPATE° ON 10/s/26, e:43 AM
1 OF 4
CHECKLISTS
Fire Service Features
Status Code
Fail
505.1- Address identification.
New and existing buildings shall be provided with approved
address identification. The address identification shall be
legible and placed in a position that is visible from the street
or road fronting the property. Address identification
characters shall contrast with their background. Address
numbers shall be Arabic numbers or alphabetical letters.
Numbers shall not be spelled out. Each character shall be not
less than 4 inches (102 mm) high with a minimum stroke
width of 1/2 inch (12.7 mm). Where required by the fire code
official, address identification shall be provided in additional
approved locations to facilitate emergency response. Where
access is by means of a private road and the building cannot
be viewed from the public way, a monument, pole or other
sign or means shall be used to identify the structure. Address
identification shall be maintained.
Additional Codes
Starts Code
Fail
603.1- General.
Electrical equipment, wiring and systems required by this
code or the International Building Code shall be installed,
used and maintained in accordance with NFPA 70 and
Sections 603.2 through 603.10.
Electrical Safety
_« Code
Fail
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
Description
Location: Front of building
Comments: Provide address identification numbers on the building
facing the road in contrast with the building to be easily legible.
Description
Location: Bar - Coffee Maker
Comments: Remove coffee maker from plugged to power strip.
Appliances with heating elements shall plug directly to an outlet
Description
Location: Bar
Comments: Power strip hanging from extinguisher shall be properly
mounted or supported to avoid hanging by wires.
GENERATED ON 10/8/2C, 8 43 AM
2 OF 4
Portable Fire Extingusihers
Status Code
Fall
906.2 • General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies, 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Fail 906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description
Location: Office
Comments: Provide Inspector access to locked office.
Location: Kitchen
Comments: Provide annual service to extinguisher, currently past
due.