COMMERCIAL FIRE INSPECTION - 2100-2102 LAFAYETTE AV-
10/07/26
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 1
$100.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
13067
10/12/2026
11/16/2026
2027-00000170
$ 100.00
Less Prepayment
Total Due -*
City of Waterloo
$0.00
$100.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Neighborhood Mart - 2100-2102 Lafayette AVE, BLDG 2100-2102 Lafayette Ave,
Waterloo IA 50703
INSPECTION DETAILS
425 E. 3rd Street
Inspection Date Inspection Type Inspection Number
10107/2026 Annual Inspection (1Yr)_j RE►NSPECTION) i2D(2q loopo 20540-R1
Lead Inspector
BRAD BALDWIN
Other Inspectors
NIA
Shiti
NIA
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 0 0 2 0 14
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 10/07/2026 @ 15:45
Reinspection Date
11104/2026
$100 re -inspection fee for failure to complete corrections on scheduled 10/7126 inspection. Complete corrections to avoid fees at following inspection.
BRAD BALDWIN - 0911512026 @ 08:16
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 0911512026 @ 08:16
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and 5200 for all subsequent re -inspections.
BRAD BALDWIN - 09115/2026 @ 08:16
Fire extinguishers due annually serviced in September 2026
BRAD BALDWIN - 09/1512026 @ 08:16
• $80 annual inspection fee
BRAD BALDWIN - 09115/2026 @ 08:16
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
Muhammad "John" Sarwar
Date: BRAD BALDWIN 10/07/202G
GENERATED ON 10/7/20, 3:47 PH
1 OF 1(1
CHECKLISTS
GENERATED ON 10/7/28, 3:47 PM
2 OF 10
Reinspection
StaIt is Code
Fall
1010.2.4 - Locks and latches.
Locks and latches shall be permitted to prevent operation of
doors where any of the following exist: 1.Places of detention
or restraint. 2.In Group 1-1, Condition 2 and Group 1-2
occupancies where the clinical needs of persons receiving
care require containment or where persons receiving care
pose a security threat, provided that all clinical staff can
readily unlock doors at all times, and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times. 2. 3. In buildings in occupancy Group A
having an occupant load of 300 or less, Groups 8, F, M and S,
and in places of religious worship, the main door or doors are
permitted to be equipped with key -operated locking devices
from the egress side provided: 2.1. 3.1. The locking device is
readily distinguishable as locked. 2.2. 3.2. A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch
(25 mm) high on a contrasting background. 2.3. 3.3. The use
of the key -operated locking device is revocable by the fire
code official for due cause. 3. 4. Where egress doors are used
in pairs, approved automatic flush bolts shall be permitted to
be used, provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface -mounted
hardware. 4. 5. Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch, dead
bolt or security chain, provided such devices are openable
from the inside without the use of a key or tool. 5. 6. Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures. 6. 7. Doors serving roofs not intended to be
occupied shall be permitted to be locked, preventing entry to
the building from the roof. 8.Other than egress courts, where
occupants must egress from an exterior space through the
building for means of egress, exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following: 8.1.The maximum occupant load shall be posted
where required by Section 1004.9. Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways. 8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side. 8.3.The egress door locking
device is readily distinguishable as locked and shall be a key -
operated locking device. 8.4.A clear window or glazed door
opening, not less than 5 square feet (0.46 m2) in area, shall
be provided at each exit access door to determine if there are
occupants using the outdoor area. 8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating: "THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on
the sign shall be not less than 1 inch (25.4 mm) high on a
contrasting background. 8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004. 9.Locking devices are
permitted on doors to balconies, decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet (23.23
m2) or less, serving a private office space.
Description
Location: Front exit door
Comments: Provide permanent approved signage indicating 'THIS
DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" or other
approved wording on interior of door. Paper or laminated paper will
not be accepted.
Additional comments: No progress - 1017/26
GENERATED ON 10/7/26, 3:47 PM
3 OF 10
Fail
Fail
Fail
102.4 • Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes In use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
1020.3 - Width and capacity.
The required capacity of corridors shall be determined as
specified in Section 1005.1, but the minimum width shall be
not less than that specified in Table 1020.3. Exception: In
Group 1-2 occupancies, corridors are not required to have a
clear width of 96 inches (2438 mm) in areas where there will
not be stretcher or bed movement for access to care or as
part of the defend -in -place strategy.
Location: Back storage area
Comments: Licensed plumbing contractor shall obtain permit and
Inspection for water heater Installed without permit. Manufacture date
of Oct. 2025
Additional comments: No progress • 1017/26
Location: Kitchen
Comments: Licensed plumbing contractor shall obtain permit and
inspection for water heater (50 Gallon) installed without permit.
Manufacture date of July 2025
Additional comments: No progress - 10/7/26
Location: Back office
Comments: A clear unobstructed (24 inches in width minimum) path
to electric panels shall be maintained.
Additional comments: No progress - 1017/26
GENERATED ON 10/7/26, 3:47 PN 4 OF 10
Fall
Fail
Fail
5303.5.3 • Securing compressed gas containers, cylinders
and tanks.
Compressed gas containers, cylinders and tanks shall be
secured to prevent falling caused by contact, vibration or
seismic activity. Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers, cylinders and tanks to a fixed object
with one or more restraints. 2.Securing containers, cylinders
and tanks on a cart or other mobile device designed for the
movement of compressed gas containers, cylinders or tanks.
3. Nesting of compressed gas containers, cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public. Nesting shall be allowed
provided that the nested containers, cylinders or tanks, if
dislodged, do not obstruct the required means of egress.
4.Securing of compressed gas containers, cylinders and
tanks to or within a rack, framework, cabinet or sirnilar
assembly designed for such use. Exception: Compressed gas
containers, cylinders and tanks in the process of
examination, filling, transport or servicing.
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Location: Kitchen
Comments: Secure all compressed gas cylinders with chain to avoid
tip over.
Additional comments: No progress-1017126
Location: Kitchen - Black & Decker "toaster"
Comments: Verify appliance is commercially listed. If approved,
appliances including heat producing elements or motors shall plug
directly to a permanent outlet. Remove appliance from building if
found to be listed for "residential use only"
Location: Lunchables cooler
Comments: Provide listed cord protector to avoid possible damage to
cord over walkway.
Additional comments: No progress-1017126
GENERATED ON te/7/2e, 3:47 PM
5 OF 10
Fall
Fail
U
603.2 - Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated. Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Location: Exterior neon lighting
Comments: Exposed neon lighting shall be properly disconnected or
repaired
Additional comments: No progress - 10/7/26
Location: Back office - ceiling
Comments: Electrical connections shall be properly capped and box
cover installed.
Additional comments: No progress - 10/7/26
GENERATED ON 10/7/26, 3:47 PM
6 OF 10
Fall
0
603.2.2 • Unapproved conditlonsOpen electrical terminations.
Open Junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Location: Front of building • Exterior
Comments: Licensed electrical contractor shall properly cap wires In
box with cover. Obtain copy of invoice from contractor to provide for
inspector.
Additional comments: No progress -10/7/26
GENERATED ON 10/7/20, 3:47 PM
7 OF 10
Fail
Fa i I
Fail
603.4 • Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
603.4.1- Labeling.
Doors into electrical control panel rooms shall be marked
with a plainly visible and legible sign stating "ELECTRICAL
ROOM" or similar approved wording. The disconnecting
means for each service, feeder or branch circuit originating
on a switchboard or panelboard shall be legibly and durably
marked to indicate its purpose unless such purpose is clearly
evident. Where buildings or structures are supplied by more
than one power source, markings shall be provided at each
service equipment location and at all interconnected electric
power production sources identifying all electric power
sources at the premises in accordance with NFPA 70.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Location: Back office
Comments: Remove storage within 36 Inches of electric panels.
Maintain proper clearances at all times.
Additional comments: No progress -10/7/26
Location: Back office - door
Comments: Provide permanent approved signage on door indicating
"ELECTRIC ROOM" or other approved wording. Laminated paper will
not be accepted.
Additional comments: No progress -10/7/26
Location: Behind register counter - Above "Jack Daniels" shelving
Comments: Black flexible supply cord extending above ceiling shall
be removed from above ceiling. Flexible supply cords shall not pass
through concealed spaces.
Additional comments: No progress - 10/7/26
GENERATED ON 10/7/2G, 3:47 PN
8 OF 10
Additional Codes
Stays Code
Fall 305.1 - Clearance from ignition sources.
Clearance between ignition sources, such as luminaires,
heaters, flame -producing devices and combustible materials,
shall be maintained In an approved manner.
Description
Location: Kitchen
Comments: Remove all combustible material from within 36" of water
heater. Maintain clearances at all times,