Loading...
HomeMy WebLinkAboutNEIGHBORHOOD MART-2100-2102 LAFAYETTE STO W4 4. aar�� �A O INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/12/2026 11/16/2026 2027-00000170 $100.00 Customer #: 13067 NEIGHBORHOOD MART 2100 LAFAYETTE ST WATERLOO, IA 50703 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 2100-2102 LAFAYETTE AV- 10/07/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13067 10/12/2026 11/16/2026 2027-00000170 $ 100.00 Less Prepayment Total Due -* City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Neighborhood Mart - 2100-2102 Lafayette AVE, BLDG 2100-2102 Lafayette Ave, Waterloo IA 50703 INSPECTION DETAILS 425 E. 3rd Street Inspection Date Inspection Type Inspection Number 10107/2026 Annual Inspection (1Yr)_j RE►NSPECTION) i2D(2q loopo 20540-R1 Lead Inspector BRAD BALDWIN Other Inspectors NIA Shiti NIA Station Unit NIA NIA SUMMARY OF INSPECTION 0 0 0 2 0 14 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10/07/2026 @ 15:45 Reinspection Date 11104/2026 $100 re -inspection fee for failure to complete corrections on scheduled 10/7126 inspection. Complete corrections to avoid fees at following inspection. BRAD BALDWIN - 0911512026 @ 08:16 • Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN - 0911512026 @ 08:16 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and 5200 for all subsequent re -inspections. BRAD BALDWIN - 09115/2026 @ 08:16 Fire extinguishers due annually serviced in September 2026 BRAD BALDWIN - 09/1512026 @ 08:16 • $80 annual inspection fee BRAD BALDWIN - 09115/2026 @ 08:16 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Muhammad "John" Sarwar Date: BRAD BALDWIN 10/07/202G GENERATED ON 10/7/20, 3:47 PH 1 OF 1(1 CHECKLISTS GENERATED ON 10/7/28, 3:47 PM 2 OF 10 Reinspection StaIt is Code Fall 1010.2.4 - Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exist: 1.Places of detention or restraint. 2.In Group 1-1, Condition 2 and Group 1-2 occupancies where the clinical needs of persons receiving care require containment or where persons receiving care pose a security threat, provided that all clinical staff can readily unlock doors at all times, and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times. 2. 3. In buildings in occupancy Group A having an occupant load of 300 or less, Groups 8, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side provided: 2.1. 3.1. The locking device is readily distinguishable as locked. 2.2. 3.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch (25 mm) high on a contrasting background. 2.3. 3.3. The use of the key -operated locking device is revocable by the fire code official for due cause. 3. 4. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts does not have a doorknob or surface -mounted hardware. 4. 5. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool. 5. 6. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures. 6. 7. Doors serving roofs not intended to be occupied shall be permitted to be locked, preventing entry to the building from the roof. 8.Other than egress courts, where occupants must egress from an exterior space through the building for means of egress, exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following: 8.1.The maximum occupant load shall be posted where required by Section 1004.9. Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways. 8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side. 8.3.The egress door locking device is readily distinguishable as locked and shall be a key - operated locking device. 8.4.A clear window or glazed door opening, not less than 5 square feet (0.46 m2) in area, shall be provided at each exit access door to determine if there are occupants using the outdoor area. 8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on the sign shall be not less than 1 inch (25.4 mm) high on a contrasting background. 8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004. 9.Locking devices are permitted on doors to balconies, decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet (23.23 m2) or less, serving a private office space. Description Location: Front exit door Comments: Provide permanent approved signage indicating 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" or other approved wording on interior of door. Paper or laminated paper will not be accepted. Additional comments: No progress - 1017/26 GENERATED ON 10/7/26, 3:47 PM 3 OF 10 Fail Fail Fail 102.4 • Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes In use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 102.4 - Application of building code. The design and construction of new structures shall comply with the International Building Code , and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code , shall be made in accordance therewith. 1020.3 - Width and capacity. The required capacity of corridors shall be determined as specified in Section 1005.1, but the minimum width shall be not less than that specified in Table 1020.3. Exception: In Group 1-2 occupancies, corridors are not required to have a clear width of 96 inches (2438 mm) in areas where there will not be stretcher or bed movement for access to care or as part of the defend -in -place strategy. Location: Back storage area Comments: Licensed plumbing contractor shall obtain permit and Inspection for water heater Installed without permit. Manufacture date of Oct. 2025 Additional comments: No progress • 1017/26 Location: Kitchen Comments: Licensed plumbing contractor shall obtain permit and inspection for water heater (50 Gallon) installed without permit. Manufacture date of July 2025 Additional comments: No progress - 10/7/26 Location: Back office Comments: A clear unobstructed (24 inches in width minimum) path to electric panels shall be maintained. Additional comments: No progress - 1017/26 GENERATED ON 10/7/26, 3:47 PN 4 OF 10 Fall Fail Fail 5303.5.3 • Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers, cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers, cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers, cylinders or tanks. 3. Nesting of compressed gas containers, cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public. Nesting shall be allowed provided that the nested containers, cylinders or tanks, if dislodged, do not obstruct the required means of egress. 4.Securing of compressed gas containers, cylinders and tanks to or within a rack, framework, cabinet or sirnilar assembly designed for such use. Exception: Compressed gas containers, cylinders and tanks in the process of examination, filling, transport or servicing. 603.1.1- Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, wiring, devices and appliances shall be tested; and listed by an approved agency and labeled; and installed, used and maintained in accordance with NFPA 70 and all instructions included as part of such listing. 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Location: Kitchen Comments: Secure all compressed gas cylinders with chain to avoid tip over. Additional comments: No progress-1017126 Location: Kitchen - Black & Decker "toaster" Comments: Verify appliance is commercially listed. If approved, appliances including heat producing elements or motors shall plug directly to a permanent outlet. Remove appliance from building if found to be listed for "residential use only" Location: Lunchables cooler Comments: Provide listed cord protector to avoid possible damage to cord over walkway. Additional comments: No progress-1017126 GENERATED ON te/7/2e, 3:47 PM 5 OF 10 Fall Fail U 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Exterior neon lighting Comments: Exposed neon lighting shall be properly disconnected or repaired Additional comments: No progress - 10/7/26 Location: Back office - ceiling Comments: Electrical connections shall be properly capped and box cover installed. Additional comments: No progress - 10/7/26 GENERATED ON 10/7/26, 3:47 PM 6 OF 10 Fall 0 603.2.2 • Unapproved conditlonsOpen electrical terminations. Open Junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Location: Front of building • Exterior Comments: Licensed electrical contractor shall properly cap wires In box with cover. Obtain copy of invoice from contractor to provide for inspector. Additional comments: No progress -10/7/26 GENERATED ON 10/7/20, 3:47 PM 7 OF 10 Fail Fa i I Fail 603.4 • Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70. 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). 603.4.1- Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Back office Comments: Remove storage within 36 Inches of electric panels. Maintain proper clearances at all times. Additional comments: No progress -10/7/26 Location: Back office - door Comments: Provide permanent approved signage on door indicating "ELECTRIC ROOM" or other approved wording. Laminated paper will not be accepted. Additional comments: No progress -10/7/26 Location: Behind register counter - Above "Jack Daniels" shelving Comments: Black flexible supply cord extending above ceiling shall be removed from above ceiling. Flexible supply cords shall not pass through concealed spaces. Additional comments: No progress - 10/7/26 GENERATED ON 10/7/2G, 3:47 PN 8 OF 10 Additional Codes Stays Code Fall 305.1 - Clearance from ignition sources. Clearance between ignition sources, such as luminaires, heaters, flame -producing devices and combustible materials, shall be maintained In an approved manner. Description Location: Kitchen Comments: Remove all combustible material from within 36" of water heater. Maintain clearances at all times, GENERATED ON 140/7/2G, P;:47 PM 9 OF 10 0 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.0O Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 10/7/26, 3:47 PM 10 OF 10