COMMERCIAL FIRE INSPECTION - 1625 W 4TH ST-10/07/26
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 2,000
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
13354
10/12/2026
11/16/2026
2027-00000184
$80.00
Less Prepayment
Total Due --
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
New Star - 1625 W 4th ST, BLDG 1625 W 4th St, Waterloo IA 50702
INSPECTION DETAILS
Inspection Date
10/07/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other inspectors
N/A
Shift
NIA
425 E. 3rd Street
480 ,e.() Inspection Number
19009
Station Unit
NIA N/A
SUMMARY OF INSPECTION
0 32
Passed codes
NEXT STEPS
0 6
Failed codes
Q 37
N/A codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 10108/2026 @ 08:16
Reinspection Date
11/05/2026
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and $200 for all subsequent re -inspections.
BRAD BALDWIN - 1010812026 @ 08:15
• Provide corrections to avoid progressive re -inspection fees beginning at $100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 10108/2026 @ 08:15
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224
BRAD BALDWIN - 10108/2026 @ 08:15
• $80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
Mamoon Amhtar 2025
CHECKLISTS
No signature
Report completed post inspection
RE
Date: BRAD BALDWIN 10108/2026
GEMEPATEU 6N IFVN/74, 1 OF 6
General Housekeeping
Status Code
Fail
305.1- Clearance from ignition sources.
Clearance between ignition sources, such as luminaires,
heaters, flame -producing devices and combustible materials,
shall be maintained in an approved manner.
Additional Codes
Status Code
Fail 603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
Fail
ail
603.1.1- Equipment and fixtureswiring.
Electrical equipment and fixtures All electrical equipment,
wiring, devices and appliances shall be tested; and listed by
an approved agency and labeled; and installed, used and
maintained in accordance with NFPA 70 and all instructions
included as part of such listing.
Description
Location: Mechanical room
Comments: Remove all combustible storage within 3 feet from
furnace.
Description
Location: Espresso Machine
Comments: Paperwork states "Household Use Only", non
commercially listed equipment shall be removed from use in the
building.
Moot p,rchose lows» -.
le below
'To Do etet G°Ce (see (see example mplebelow)
Access Code
CHEFmpfl
ADORMS�bdQ
tOOjU
xTxx
Coast
02D.16
CG1U110N DO NOTSTP EW AIER
AMNION NE PAS Ptc1401R DANS LtAU
WARNRIO TO PREYENNT TTC SMOCK,
UNPLUG Kr
• qt ItR NSC110CS DECIRIQIIES,
.. Iiwa4E\ AVANE DE I UI IUSER
POIN USING
AVANT DE
S1 LINEN
U$OTt WW1 depict- ed here is an e-
PieaSe 660 10001 0h yOuV pfodJCt for actual rnod6'i
Location: Ice Machine
Comments: Provide documentation of commercial listed appliance,
non commercially listed equipment shall be removed from use in the
building.
0€NEPATE0 ON 10/8/26, 8:1R AM
2 OF 6
Electrical Safety
Status Code
Fall
603.2 • Abatement of unsafe conditions and electrical
hazards.
Identified electrical hazards shall be abated, Identified
hazardous electrical conditions in permanent wiring shall be
brought to the attention of the responsible code official.
Electrical wiring, devices, appliances and other equipment
that is modified or damaged and constitutes Conditions that
constitute an electrical shock or fire hazard shall be abated
not be used.
Description
Location: Exterior (front of building)
Comments: Licensed electrician shall make necessary repairs for
improper Installation (see photo attached) to comply with electrical
code. Retain copy of invoice from electrician for inspector.
GENERATED ON 10/8/26, 8:18 AM
3 OF 6
Fall
603.4 • Working space and clearancesclearance.
A working space of not Working space around electrical
equipment shall be provided in accordance with Section
110.26 of NFPA 70 for electrical equipment rated 1,000 volts or
less, and Section 110.33 of NFPA 70 for electrical equipment
rated over 1,000 volts. The minimum required working space
shall be not less than 30 inches (762 mm) in width, 36 inches
(914 mm) in depth and 78 inches (1981 mm) in height shall be
providedin front of electrical service equipment. Where the
electrical service equipment is wider than 30 inches (762
mm), the minimum working space shall be not less than the
width of the equipment. Storage of materials shall not be
located within the designated working space. Exceptions: 1.
Where other dimensions are required or allowed by NFPA 70.
2. Access openings into attics or under -floor areas that
provide a minimum clear opening of 22 inches (559 mm) by 30
inches (762 mm).
Location: Back storage
Comments: Relocate shelving and totes to maintain 36" in front of
panel for access
GENEPATE9 ON 10/8/20, s3;18 Al
4 OF 6
Portable Fire Extingusihers
Status Code
Fall
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained In accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed. 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group I-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description
Location: Extinguishers
Comments: Provide annual service to extinguishers, currently due
month of October 2026
GENERATED ON 10/8/28, 6:18 AM
5 OF 6
Statement of Fees
FEE
Invoice Date Inspection Fee
NIA $80.00
Invoice Number
NIA
Date Paid Amount Paid
Check Number Transaction Number
NIA NIA
GENERATED ON 10/8/26, 8:18 AN 6 OF 6