Loading...
HomeMy WebLinkAboutTHREE STOOGES, LKLC-2410 CROSSROADS BLVDINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/12/2026 11/16/2026 2027-00000171 $100.00 Customer #: 25100 THREE STOOGES, LLC P.O. BOX 203 Waterloo, IA 50704 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 2410 CROSSROADS BLVD- 10/06/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 25100 10/12/2026 11/16/2026 2027-00000171 $100.00 Less Prepayment Total Due -* City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Neighborhood Home - 2410 Crossroads BLVD, BLDG 2410 Crossroads Blvd, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 1010612026 Inspection Type Annual Inspection (1Yr) 425 E. 3rd Street 3 3-66r LI, C, Inspection Number a S 10 b 4 1 r .�° 24566 Lead Inspector Shift BRAD BALDWIN NIA Other Inspectors NIA Station NIA Unit NIA SUMMARY OF INSPECTION 0 35 ® 22 ®26 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES Reinspection Date 11/0612026 BRAD BALDWIN - 1010612026 @ 07:51 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN -1010612026 @ 07:51 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224 BRAD BALDWIN - 1010612026 @ 07:51 • $100 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Brody Knutson 2026 CHECKLISTS Date: BRAD BALDWIN 10107/2026 GENERATED ON 10/7/20, 2:35 PM 1 OF 10 Additional Codes Status Code Fail Fail 1010.2 - Door operations. Except as specifically permitted by this section, egress do )rs shall be readily openable from the egress side without the use of a key or special knowledge or effort. 1010.2.1 - Unlatching. The unlatching of any door or leaf for egress shall require not require more than one operation motion in a single linear or rotational direction to release all latching and all locking devices. Exceptions: 1.Places of detention or restraint. 2.Where manually operated bolt locks are permitted by Section 1010.2.5. 3.Doors with automatic flush bolts as permitted by Section 1010.2.4, Item 3 4. 4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4, Item 4 5. Descrip1 on Location: Dock (interior) door Comments: Remove key lock from door. Location: Dock (exterior) exit door Comments: Required exit doors shall not include more than a single motion to unlock and unlatch door to exit, currently two motions exist. Corrections shall be made to comply with exit door requirements. Replacement of required exit door or lock/latch hardware requires permit and inspection. GENERATED ON 10/7/26, 2:35 PM 2 OF 10 Fall 0 1010.2.4 - Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exist: S.Places of detention or restraint. 2.In Group 1-1, Condition 2 and Group 1.2 occupancies where the clinical needs of persons receiving care require containment or where persons receiving care pose a security threat, provided that all clinical staff can readily unlock doors at all times, and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times. 2. 3. In buildings In occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship, the main door or doors are permitted to be equipped with key -operated locking devices from the egress side provided: 2.1. 3.1. The locking device is readily distinguishable as locked. 2.2.3.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." The sign shall be In letters 1 inch (25 mm) high on a contrasting background. 2.3. 3.3. The use of the key -operated locking device is revocable by the fire code official for due cause. 3.4. Where egress doors are used in pairs, approved automatic Rush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts does not have a doorknob or surface -mounted hardware. 4. 5. Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch, dead bolt or security chain, provided such devices are openable from the inside without the use of a key or tool. 5. 6. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures. 6. 7. Doors serving roofs not intended to be occupied shall be permitted to be locked, preventing entry to the building from the roof. 8.Other than egress courts, where occupants must egress from an exterior space through the building for means of egress, exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following: 8.1.The maximum occupant load shall be posted where required by Section 1004.9. Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways. 8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side. 8.3.The egress door locking device is readily distinguishable as locked and shall be a key - operated locking device. 8.4.A clear window or glazed door opening, not less than 5 square feet (0.46 m2) in area, shall be provided at each exit access door to determine if there are occupants using the outdoor area. 8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating: "THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on the sign shall be not less than 1 inch (25.4 mm) high on a contrasting background. 8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants In accordance with Section 1004. 9.Locking devices are permitted on doors to balconies, decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet (23.23 m2) or less, serving a private office space. Location: North and East exit doors Comments: Provide permanent approved signage indicating "THIS DOOR SHALL REMAIN UNLOCKED WHILE OCCUPIED" or other approved wording on exterior exit doors. Laminated paper will not be accepted. GENERATED ON 10/7/24, 2:05 PM 3 OF 10 Fail 901.4.7.2 - Marking on access doors. Access doors for automatic sprinkler system riser rooms and fire pump rooms shall be labeled with an approved sign. The lettering shall be in contrasting color to the background. Letters shall have a minimum height of 2 inches (51 mm) with a minimum stroke of 3/8 inch (10 mm). Fire Alarm System Status Fail Code Chapter 14 - Inspection, testing, and maintenance Fire alarm system tested at least annually by licensed contractor Fire Sprinkler System Status Fail Code 5.2.1 - Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed contractor Location: West exterior door - Sprinkler Riser Room Comments: Permanent approved signage shall be installed on exterior side of door indicating "FACP" and "SPRINKLER RISER". Signls shall include red background with white lettering. Laminated paper will not be accepted as permanent. FIRE ALARM CONTROL PANEL SPRINKLER RISER ROOM Description Location: Fire Alarm Comments: Licensed alarm contractor shall complete annual inspection and upload report to Compliance Engine including deficiencies corrected. Currently no record of last inspection. Description Location: Sprinkler system Comments: Required annual inspection by licensed contractor shall be completed with report including deficiencies corrected to be uploaded to Compliance Engine. Last recorded inspection on 8/28123 GENERATED ON 10/7/20, 2:35 PM 4 OF 10 Fire Service Features Status Code Fall Fail Fail Fail 506.2 - Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed. The key to such lock shall be secured in the key box. 509.1- Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves, or other fire detection, suppression or control elements fire protection systems shall be identified for the use of the fire department. Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 509.2 - Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Description Location: Knox Box Comments: Contact Waterloo Fire Dept at 319.291.4460 to update all required keys in Knox Box. Keys to Sprinkler Riser room shall be included. Location: Sprinkler riser room Comments: Interior door separating Riser Room and Fire Alarm Control Panel shall have permanent approved "FACP" signage installed on Riser Room side. Laminated paper will not be accepted. FACP Location: Sprinkler Riser Room Comments: Remove storage within 36" of sprinkler system and maintain clear path of access for fire fighters at all times. Location: Fire Alarm Panel Comments: Remove storage of doors and all obstructions within 36" of alarm panel and maintain clear ready access to panel at all times. GENERATED ON 10/7/26, 2:35 PM 5 OF 10 Electrical Safety sra_lis code Fail 603.2 - Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Description Location: Behind "Flexsteel Linden" couch Comments: Licensed electrician shall make necessary repairs to damaged receptacle (see photo). Retain copy of invoice from electrician for inspector. Also, remove extension cord. GENERATED ON 10/7/26, 2:35 PM 6 OF 1e Fail Fail Fail Fail 603.2 • Abatement of unsafe conditions and electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.4 - Working space and clearancesclearance. A working space of not Working space around electrical equipment shall be provided in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less, and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts. The minimum required working space shall be not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be providedin front of electrical service equipment, Where the electrical service equipment is wider than 30 inches (762 mm), the minimum working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1. Where other dimensions are required or allowed by NFPA 70, 2. Access openings into attics or under -floor areas that provide a minimum clear opening of 22 inches (559 mm) by 30 inches (762 mm). Location: Recliner post near register area Comments: Provide knockout plug for opening in box Location: Lift chair area Comments: Replace missing outlet cover below painting. Location: Sales floor - Behind "5Z Pittson Anchor" couch Comments: Replace missing outlet cover Location: Utility Room Comments: Remove storage within 36" of electric panels and equipment, maintain proper clearances at all times. GENERATED ON 10/7/25, 2:35 PM 7 OF 10 Fail 603.4.1- Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. The disconnecting means for each service, feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Where buildings or structures are supplied by more than one power source, markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail Fail Fail Fail 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Location: Main electric room 1 Sprinkler Riser Room Comments: Permanent approved signage shall be installed Indicating "ELECTRIC ROOM" or other approved wording on or near interior door. Location: Lift chair area Comments: Remove extension cord. may replace with properly supported power strip with manual reset for low wattage electronics only. Location: Adjustable base area Comments: Remove extension cord. Location: Sales floor - Display west of north exit door Comments: Remove extension cord. may replace with properly supported power strip with manual reset for low wattage electronics only. Location: Sales floor - Desk area Comments: Remove red extension cord and power strip in extension cord. Power strips shall plug directly to an outlet. GENERATED ON 10/7/25, 2,35 RN eori- Portable Fire Extingusihers Status Fail Fail O Code Description 906.2 • General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A•5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. 906.6 - Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Location: Entire building Comments: Provide required annual service to all extinguishers in building. Last serviced in June 2022 Location: Utility Room Comments: Remove storage obstructing ready access to extinguisher. OENEPATED ON 10/7/26, 2:35 PM 9 OF 10 0 Statement of Fees FEE Invoice Date Inspection Fee NIA $100.00 Date Paid Amount Paid Invoice Number Check Number Transaction Number N►A NIA NIA GENERATED ON 10/7/25, 2:35 PM 10 OF 10