COMMERCIAL FIRE INSPECTION - 3631 W 9TH ST-10/14/26
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
INSPECTION 1 HH
OCCUPANCY FEE
$70.00
$10.00
CUSTOMER #
BILLING DATE
DUE DATE
INVOICE #
CHARGES
24164
10/14/2026
11/20/2026
2027-00000185
$80.00
Less Prepayment
Total Due —>
City of Waterloo
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
It Takes A Village Childcare - 3631 W 9th ST, BLDG 3631
50702
INSPECTION DETAILS
Inspection Date
10/14/2026
Lead Inspector
JEREMIAH VANDYKE
425 E. 3rd Street
h St., Waterloo IA
Inspection TypeOR / 1 _ Inspection Number
Annual Inspection (1Yr) L 17608
Other Inspectors
NIA
Shift
N/A
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 45
Passed codes
NEXT STEPS
U 3
Failed codes
26
N/A codes
Please direct questions about your Inspection to:
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
GENERAL NOTES
JEREMIAH VANDYKE - 10/1412026 @ 09:27
Inspection Fee = $80.00 (To be mailed out by City via snail mail.)
JEREMIAH VANDYKE - 10/14/2026 @ 09:27
Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615
JEREMIAH VANDYKE - 10114/2026 @ 09:26
Reinspection Date
11113/2026
Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are
Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed
the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees
may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.-
JEREMIAH VANDYKE - 10/14/2026 @ 08:49
Fire extinguisher
GENERATED ON 10/14/26, 0;20 AM 1 OF 4
JEREMIAH VANDYKE - 1011412026 @ 08:47
55 currently enrolled
JEREMIAH VANDYKE - 1011412026 @ 08:47
Fire drill 9115 recorded and logged
SIGNATURES
Contact signature
No signature
Report completed post inspection
Florence Miller
CHECKLISTS
Means of Egress
.,. _ Code
Inspector signature
Date: JEREMIAH VANDYKE
Fail 1032.2 - Reliability.
Required exit accesses, exits and exit discharges shall be
continuously maintained free from obstructions or
impediments to full instant use in the case of fire or other
emergency where the building area served by the means of
egress is occupied. An exit or exit passageway shall not be
used for any purpose that interferes with a means of egress.
Description
Location: Red room exterior door to outdoor play area.
Comments: Hard to open - Door needs fixed and repaired.
1011412026
GENERATED ON 10/14/26, G:29 AM
2 OF 4
Additional Codes
Status Code
Fail
610.1.2 - Maintenance.
The lint trap, mechanical and heating components, and the
exhaust duct system of a clothes dryer shall be maintained in
accordance with the manufacturer&0/039;s operating
instructions to prevent the accumulation of lint or debris that
prevents the exhaust of air and products of combustion.
Portable Fire Extingusihers
Status Code
Fail
906.2 - General requirements.
Portable fire extinguishers shall be selected, installed and
maintained in accordance with this section and NFPA 10.
Exceptions: 1.The distance of travel to reach an extinguisher
shall not apply to the spectator seating portions of Group A-5
occupancies. 2.Thirty-day inspections shall not be required
and maintenance shall be allowed to be once every 3 years
for dry -chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved
electronic monitoring device, provided that all of the
following conditions are met: 2.1.Electronic monitoring shall
confirm that extinguishers are properly positioned, properly
charged and unobstructed, 2.2.Loss of power or circuit
continuity to the electronic monitoring device shall initiate a
trouble signal. 2.3.The extinguishers shall be installed inside
of a building or cabinet in a noncorrosive environment.
2.4.Electronic monitoring devices and supervisory circuits
shall be tested every 3 years when extinguisher maintenance
is performed. 2.5.A written log of required hydrostatic test
dates for extinguishers shall be maintained by the owner to
verify that hydrostatic tests are conducted at the frequency
required by NFPA 10. 3.In Group 1-3, portable fire
extinguishers shall be permitted to be located at staff
locations.
Description
Location: Clothes dryer needs cleaned. Last serviced by Harris
412512025.
Comments: Send plc of invoice after serviced.
Description
Location: Need to service fire extinguisher in FACP room.