Loading...
HomeMy WebLinkAboutIT TAKES A VILLAGE CHILDCARE-3631 W 9TH ST-10/14/26Tilt INVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/14/2026 11/20/2026 2027-00000185 $80.00 Customer #: 24164 IT TAKES A VILLAGE CHILDCARE 3631 W 9TH ST WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 3631 W 9TH ST-10/14/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 1 HH OCCUPANCY FEE $70.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 24164 10/14/2026 11/20/2026 2027-00000185 $80.00 Less Prepayment Total Due —> City of Waterloo $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report It Takes A Village Childcare - 3631 W 9th ST, BLDG 3631 50702 INSPECTION DETAILS Inspection Date 10/14/2026 Lead Inspector JEREMIAH VANDYKE 425 E. 3rd Street h St., Waterloo IA Inspection TypeOR / 1 _ Inspection Number Annual Inspection (1Yr) L 17608 Other Inspectors NIA Shift N/A Station Unit NIA NIA SUMMARY OF INSPECTION 0 45 Passed codes NEXT STEPS U 3 Failed codes 26 N/A codes Please direct questions about your Inspection to: JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org GENERAL NOTES JEREMIAH VANDYKE - 10/1412026 @ 09:27 Inspection Fee = $80.00 (To be mailed out by City via snail mail.) JEREMIAH VANDYKE - 10/14/2026 @ 09:27 Lt. Van Dyke - jeremiah.vandyke@waterloo-ia.org - Work: 319-291-4460 - Cell: 319-883-1615 JEREMIAH VANDYKE - 10114/2026 @ 09:26 Reinspection Date 11113/2026 Re -inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 8:00 a.m. - 5:00 p.m. If the automatically generated re -inspection date lands on a weekend, the re -inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days, you can call to set up an earlier re -inspection. *****Re inspection fees may be assessed for subsequent re -inspections. Re -inspection fees start at $100, then $150, and $200 for all subsequent re-inspections.- JEREMIAH VANDYKE - 10/14/2026 @ 08:49 Fire extinguisher GENERATED ON 10/14/26, 0;20 AM 1 OF 4 JEREMIAH VANDYKE - 1011412026 @ 08:47 55 currently enrolled JEREMIAH VANDYKE - 1011412026 @ 08:47 Fire drill 9115 recorded and logged SIGNATURES Contact signature No signature Report completed post inspection Florence Miller CHECKLISTS Means of Egress .,. _ Code Inspector signature Date: JEREMIAH VANDYKE Fail 1032.2 - Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Description Location: Red room exterior door to outdoor play area. Comments: Hard to open - Door needs fixed and repaired. 1011412026 GENERATED ON 10/14/26, G:29 AM 2 OF 4 Additional Codes Status Code Fail 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer&0/039;s operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Portable Fire Extingusihers Status Code Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed, 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Clothes dryer needs cleaned. Last serviced by Harris 412512025. Comments: Send plc of invoice after serviced. Description Location: Need to service fire extinguisher in FACP room. GENERATED ON 10/14/26, 9:29 AM 3 OF 4 1 0 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Date Paid Amount Paid Invoice Number Check Number Transaction Number NIA NIA NIA 4 OF 4 GENERATED ON 10/14/29, 9:29 AM