COMMERCIAL FIRE INSPECTION - 611 BROADWAY ST-09/22/26
FOR BILLING INQUIRY: (319)291-4323
Description
INSPECTION 2,000
OCCUPANCY FEE
Total Price
$70.00
$10.00
CUSTOMER #
11772
BILLING DATE
DUE DATE
INVOICE #
CHARGES
10/14/2026
11/20/2026
City of Waterloo
2027-00000191
Less Prepayment
Total Due —�
$80.00
$0.00
$80.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
nspection Report
Family Dollar • 611 Broadway ST, BLDG 611 Broadway St, Waterloo IA 50703
INSPECTION DETAILS
Inspection Date
09122/2026
Lead Inspector
BRAD BALDWIN
Inspection Type
Annual Inspection (1Yr)
Other Inspectors
N/A
iTIA
Shift
NIA
425 E. 3rd Street
Inspection Number
11618
Station Unit
NIA NIA
SUMMARY OF INSPECTION
0 29
Passed codes
NEXT STEPS
C�10 ®36
Failed codes N/A codes
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 09/24/2026 @ 08:46
Fire extinguishers due annually serviced in January 2027
BRAD BALDWIN - 09/24/2026 @ 08:46
Reinspection Date
10/2212026
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at $100, then $150, and S200 for all subsequent re -inspections.
BRAD BALDWIN - 09124/2026 @ 08:46
• Commercial Fire Inspector - brad.baidwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224
BRAD BALDWIN - 0912412026 @ 08:46
• $80 annual inspection fee
SIGNATURES
Contact signature Inspector signature
Scott Andrews
CHECKLISTS
No signature
Report completed post inspection
Date: BRAD BALDWIN 09124/2026
GENERATED ON G/24/26, N:56 AM 1 OF 6
Means of Egress
Status Code
Fail
1010.1.3 - Door opening force Forces to unlatch and open
doors.
The force for pushing or pulling open interior swinging
egress doors, other than fire doors, shall not exceed 5
pounds (22 N). These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full -open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch -pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full -open position when
subjected to not more than a 15-pound (67 N) force.
1010.1.3 - Door opening force Forces to unlatch and open
doors.
The force for pushing or pulling open interior swinging
egress doors, other than fire doors, shall not exceed 5
pounds (22 N). These forces do not apply to the force
required to retract latch bolts or disengage other devices that
hold the door in a closed position. For other swinging doors,
as well as sliding and folding doors, the door latch shall
release when subjected to a 15-pound (67 N) force. The door
shall be set in motion when subjected to a 30-pound (133 N)
force. The door shall swing to a full -open position when
subjected to a 15-pound (67 N) force. The forces to unlatch
doors shall comply with the following: 1.Where door
hardware operates by push or pull, the operational force to
unlatch the door shall not exceed 15 pounds (66.7 N). 2.Where
door hardware operates by rotation, the operational force to
unlatch the door shall not exceed 28 inch -pounds (315 N-cm).
The force to open doors shall comply with the following:
1.For interior swinging egress doors that are manually
operated, other than doors required to be fire rated, the force
for pushing or pulling open the door shall not exceed 5
pounds (22 N). 2.For other swinging doors, sliding doors or
folding doors, and doors required to be fire rated, the door
shall require not more than a 30-pound (133 N) force to be set
in motion and shall move to a full -open position when
subjected to not more than a 15-pound (67 N) force.
Description
Location: Back storage
Comments: Repair or replace exit door that failed to open with less
than 15Ibs of force.
Location: Sales floor 2nd exit
Comments: Repair or replace exit door that failed to open with less
than 15Ibs of force. Staff not able to disarm door alarm so was not
able to test function of door opening on 9/23126
GENERATED ON O/?4/26, B;C-,4 AM
2 OF 6
Additional Codes
Status Code
Fall
102.4 • Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Emergency Equipment
Status Gale
Fail 1203.4.3 - Records.
ORecords of the inspection, testing and maintenance of
emergency and standby power systems shall include the date
of service, name of the servicing technician, a summary of
conditions noted and a detailed description of any conditions
requiring correction and what corrective action was taken.
Such records shall be maintained.
General Housekeeping
Status Code
Fail
315.3.2 - Means of egress.
Combustible materials shall not be stored in exits or
enclosures for stairways and ramps. Combustible materials in
the means of egress during construction, demolition,
remodeling or alterations shall comply with Section 3312.3.
Description
Location; HVAC permit
Comments: Contractor shall obtain Inspection for work completed.
See copy of permit attached.
Ian
��
1.4444.0,0
20wNna0liWM 04}/C06M111ger
Description
Location: Exit signs and emergency egress lighting
Comments: Provide document to inspector of testing signs and lights
including repairs made if necessary to maintain working properly.
Description
Location: Back storage
Comments: Remove all combustible material from exit path and
maintain egress path to exit clear of all obstructions at all times.
GENERATED ON 8/24/28, 8:56 AM
3 OF F
Electrical Safety
Status Code
Fail 603.2.2 - Unapproved conditionsOpen electrical terminations.
Open junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Fail
Fail
603.5.3 - Installation.
Relocatable power tap cords shall not extend through walls,
ceilings, floors, under doors or floor coverings, or be subject
to environmental or physical damage.
603.6 - Extension cords.
Extension cords and flexible cordsshall not be a substitute
for permanent wiring and shall be listed and labeled in
accordance with UL 817. Extension cords and flexible
cordsshall not be affixed to structures, extended through
walls, ceilings or floors, or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact. Extension cords shall be used only with
portable appliances. Extension cords marked for indoor use
shall not be used outdoors.
Fire Resistant Construction Maintenance
Fail
Code
704.1 - Maintaining protection.
Where required when the building was originally constructed,
materials and systems used to protect joints and voids in the
following locations shall be maintained. The materials and
systems shall be securely attached to or bonded to the
adjacent construction, without openings visible through the
construction. 1.Joints in or between fire -resistance -rated
walls, floors or floor/ceiling assemblies and roof or
rooflceiling assemblies. 2.Joints in smoke barriers. 3.Voids at
the intersection of a horizontal floor assembly and an exterior
curtain wall. 4.Voids at the intersection of a horizontal smoke
barrier and an exterior curtain wall. 5.Voids at the intersection
of a nonfire-resistance-rated floor assembly and an exterior
curtain wall. 6.Voids at the intersection of a vertical fire
barrier and an exterior curtain wall. 7.Voids at the intersection
of a vertical fire barrier and a nonfire-resistance-rated roof
assembly. Unprotected joints and voids do not need to be
protected where such joints and voids were not required to
be protected when the building was originally
constructed. Where the system design number is known, the
system shall be inspected to the listing criteria and
manufacturer's installation instructions.
Description
Location: Outlet near main exit doors
Comments: Replace missing outlet cover below extinguisher
Location: Register counter
Comments: Power strip near drink fridge shall be mounted to avoid
hanging by wires.
Location: Cabinet below register
Comments: Remove white extension cord plugged to power strip.
Description
Location: Sales floor
Comments: Replace all missing or damaged ceiling tiles above
cosmetics, hair products and dog food.
GENEPATED ON 0/24/26, 8; r, AM 4 OF 6
Portable Fire Extingusihers
Status Code
Fail
906.6 - Unobstructed and unobscured.
Portable fire extinguishers shall not be obstructed or
obscured from view. In rooms or areas In which visual
obstruction cannot be completely avoided, means shall be
provided to Indicate the locations of extinguishers.
Description
Location: Sales floor
Comments: Extinguisher signage shall be Installed at an approved
height (by inspector) to indicate location of extinguishers.
FIE
E
X
T
N
G
U
S
H
E
R
GENERATED ON 6/24/2e, 8:54 AM