Loading...
HomeMy WebLinkAboutHIBACHI SUSHI BUFFET-1535 FLAMMANG STINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/14/2026 11/20/2026 2027-00000193 $80.00 Customer #: 15391 HIBACHI SUSHI BUFFET 1535 FLAMMANG DR WATERLOO, IA 50702 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -1535 FLAMMANG ST-09/22/26 FOR BILLING INQUIRY: (319)291-4323 Description INSPECTION 2,000 OCCUPANCY FEE CUSTOMER # 15391 BILLING DATE DUE DATE INVOICE # Total Price CHARGES $70.00 $10.00 10/14/2026 11/20/2026 2027-00000193 $80.00 City of Waterloo Less Prepayment Total Due $0.00 $80.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report Hibachi Sushi Buffet • 1535 Flammang DR, BLDG 1535 Flammang Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date 09122/2026 Inspection Type Annual Inspection (1Yr) Lead Inspector Shift BRAD BALDWIN NIA Other Inspectors NIA 425 E. 3rd Street Inspection Number 24376 Station Unit N/A NIA SUMMARY OF INSPECTION 0 51 0 19 0 15 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 09122/2026 @ 14:27 Fire extinguishers due annually serviced April 2027 BRAD BALDWIN - 0912212026 @ 14:26 Annual sprinkler inspection due 1017126. Report to be uploaded to Compliance Engine BRAD BALDWIN - 0912212026 @ 14:25 Kitchen hood exhaust suppression system due for inspection on 10/14/26. Report to be uploaded to Compliance Engine BRAD BALDWIN - 09/2212026 @ 14:24 Kitchen hood exhaust cleaning due 10/16/26. Report to be uploaded to Compliance Engine Reinspection Date 10123/2026 BRAD BALDWIN - 09122/2026 @ 14:24 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 09122/2026 @ 14:24 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291.4319 (#0) - Cell: 319-230-1224 BRAD BALDWIN - 0912212026 @ 14:24 • $80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 9/24/26, 2:50 PM 1 OF 7 Wen xu - 2026 Date: _ BRAD BALDWIN 0912412026 CHECKLISTS Means of Egress Status Code Fail 1032.3 - Obstructions. A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. Description Location: West exit near bathrooms Comments: Trim trees and bushes over -growing sidewalk outside exit door GENERATED ON 9/24/26, 2:50 PM 2 OF 7 Emergency Equipment Stat rs Code Fail Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Fail 1203.2.15 - Means of egress illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008.3 and 1104.5.1. Description Location: Near hostess stand Comments: Repair or replace egress Tight that failed to Illuminate during test. Location: West dining area - above soda fountain machine Comments: Repair or replace egress Tight that failed to illuminate during test. Location: Bathroom hallway Comments: Repair or replace egress light that failed to illuminate during test. Location: Mens bathroom Comments: Repair or replace egress light that failed to illuminate during test. Location: Wornens bathroom Comments: Repair or replace egress light that failed to illuminate during test. Location: Above "Cut Table" Comments: Repair or replace egress light that failed to illuminate during test. Location: Kitchen - near fryers Comments: Replace missing egress light GENERATED ON 0/24/20, 2:50 PM 3 OF Fail 1203.2.15 - Means of egress Illumination. Emergency power shall be provided for means of egress illumination in accordance with Sections 1008,3 and 1104.5,1. Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required load for a duration of not less than 90 minutes. General Housekeeping Fail 304.3.1- Spontaneous ignition. Materials susceptible to spontaneous ignition, such as oily rags, shall be stored in a listed disposal container. Contents of such containers shall be removed and disposed of daily. Fire Sprinkler System Fail 5.2.1.1.5 - Missing escutcheons Escutcheons and coverplates for recessed, flush, and concealed sprinklers shall be replaced if found missing during the inspection. Additional Codes Fail Location: East dining area - above soda fountain machine Comments: Repair or replace egress light that failed to illuminate during test. Location: Main exit doors Comments: Repair or replace exit sign that failed to illuminate during test. Description Location: Kitchen Comments: Provide listed container with self -closing lid for disposal of soiled rags, remove from building daily. Description Location: "Lobby" dining area - Near south dining exit door Comments: Sprinkler escutcheon shall be repaired to be flush with ceiling. Corte Description 504.1 - Required access. Exterior doors and openings required by this code or the International Building Code shall be maintained readily accessible for emergency access by the fire department. An approved access walkway leading from fire apparatus access roads to exterior openings shall be provided where required by the fire code official. Location: Kitchen storage - Roof access ladder Comments: Remove storage blocking clear access to ladder, maintain area around ladder clear to access at all times. OENEPATEO ON 9/74/26, 2:50 PM 4 OF 7 Electrical Safety Status Cork Fall Fail 603.2.2 - Unapproved conditionsOpen electrical terminations. Open Junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 603.2.2 - Unapproved conditionsOpen electrical terminations. Open junction boxes and open -wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Description Location: Kitchen • North exit Comments: Licensed electrician shall repair MC cable and wire connection to exit sign. Location: Sprinkler riser room Comments: Electric box and equipment below (see photo) missing covers exposing wires shall be corrected. GENERATED ON 9/24/26, 2:50 PM 5 OF 7 Fail Fail Fail 603.5.2 - Application and usePower supply. Relocatable power taps and current taps shall be directly connected to a permanently Installed receptacle. Exceptions: 1. Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment. 2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. 603.6 - Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System STdTUS Cotle Fail 606.3.3.1- Inspection. Hoods, grease -removal devices, fans, ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. Location: Office Comments: Remove power strip plugged to another power strip behind computer. Each power strip shall plug directly to a wall outlet. Location: Pepsi fridge near sushi cooler Comments: Provide cord protector for appliance cord across walkway or relocate appliance to avoid possible damage to cord. Location: Kitchen - near fryers Comments: Extension cord extending above drop ceiling shall be removed. Description Location: Hibachi Grill Comments: Grill gas supply shall be disconnected from appliance and capped. GENERATED ON 9/?A/74, 2;05 pM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee NIA $80.00 Invoice Number NIA Date Paid Amount Paid Check Number Transaction Number NIA NIA GENERATED ON 9/24/28, 2:50 PM 7 OF 7