COMMERCIAL FIRE INSPECTION - 1604 LA PORTE RD-10/08/26
FOR BILLING INQUIRY: (319)291-4323
Description
Total Price
REINSPECTION 2
$150.00
CUSTOMER # BILLING DATE
14658
10/14/2026
DUE DATE
11/20/2026
City of Waterloo
INVOICE #
2027-00000197
Less Prepayment
Total Due
CHARGES
$150.00
$0.00
$150.00
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
Casey's General Store 42880. 1604 La Porte RD, BLDG 1604 La Porte Rd, Waterloo
IA 50702
425 E. 3rd Street
INSPECTION DETAILS
Inspection Date Inspection Type I Inspection Number
1010812028 Annual Inspection (1Yr) REINSPECTION 1ST) . 17583-R3
Lead Inspector
BRAD BALDWIN
Other Inspectors
N/A
Shift
NIA
Station
NIA
Unit
NIA
SUMMARY OF INSPECTION
G o G 1 0 5
Passed codes Resolved violations Failed codes
NEXT STEPS
Please direct questions about your Inspection to:
BRAD BALDWIN
brad.baldwin@waterloo-ia.org, 3192914319
GENERAL NOTES
BRAD BALDWIN - 1010812026 @ 12:37
Reinspection Date
1110712026
$150 re -inspection fee for failure to complete corrections on scheduled 10/8/26 inspection. Complete all corrections to avoid fees at following inspections.
BRAD BALDWIN - 0911712026 @ 14:09
Withholding re -inspection fee on 8127/26, complete corrections to avoid fees at following inspections.
BRAD BALDWIN - 09/17/2026 @ 14:09
5100 re -inspection fee for failure to complete all corrections on scheduled 9117126 inspection. Complete corrections to avoid fees at following inspections.
BRAD BALDWIN - 09/17/2026 @ 14:09
• $80 annual inspection fee
BRAD BALDWIN - 0911712026 @ 14:09
• Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#5) - Cell: 319-230-1224
BRAD BALDWIN - 0911712026 @ 14:09
• Provide corrections to avoid progressive re -inspection fees beginning at 5100. Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN - 09117/2026 @ 14:09
• If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for
inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re -
inspection fees start at 5100, then $150, and 5200 for all subsequent re -inspections.
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 10/8/28, 12:50 PM 1 OF 6
Scott (district manager) 2026 Date:
CHECKLISTS
"EF.,
BRAD BALDWIN 1010812026
GENERATED ON 1e/8/26, 12:66 PM
2 OF 6
Reinspection
Status CrcI
Fail
1010.2.4 - Locks and latches.
Locks and latches shall be permitted to prevent operation of
doors where any of the following exist: 1.Places of detention
or restraint. 2.In Group 1-1, Condition 2 and Group 1-2
occupancies where the clinical needs of persons receiving
care require containment or where persons receiving care
pose a security threat, provided that all clinical staff can
readily unlock doors at all times, and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times. 2. 3. In buildings in occupancy Group A
having an occupant load of 300 or less, Groups B, F, M and S,
and in places of religious worship, the main door or doors are
permitted to be equipped with key -operated locking devices
from the egress side provided: 2.1. 3.1. The locking device is
readily distinguishable as locked. 2.2. 3.2. A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED." The sign shall be in letters 1 inch
(25 mm) high on a contrasting background. 2.3. 3.3. The use
of the key -operated locking device is revocable by the fire
code official for due cause. 3. 4. Where egress doors are used
in pairs, approved automatic flush bolts shall be permitted to
be used, provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface -mounted
hardware. 4. 5. Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch, dead
bolt or security chain, provided such devices are openable
from the inside without the use of a key or tool. 5. 6. Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures. 6. 7. Doors serving roofs not intended to be
occupied shall be permitted to be locked, preventing entry to
the building from the roof. 8.Other than egress courts, where
occupants must egress from an exterior space through the
building for means of egress, exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following: 8.1.The maximum occupant load shall be posted
where required by Section 1004.9. Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways. 8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side. 8.3.The egress door locking
device is readily distinguishable as locked and shall be a key -
operated locking device. 8.4.A clear window or glazed door
opening, not less than 5 square feet (0.46 m2) in area, shall
be provided at each exit access door to determine if there are
occupants using the outdoor area. 8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating: "THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED." The letters on
the sign shall be not less than 1 inch (25.4 mm) high on a
contrasting background. 8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004. 9.Locking devices are
permitted on doors to balconies, decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet (23.23
m2) or less, serving a private office space.
Description
Location: Front exit door
Comments: Install signage compliant to code "THIS DOOR TO
REMAIN UNLOCKED DURING BUSINESS HOURS" on interior of
doors in approved location.
Additional comments: Doors scheduled to be delivered 11/21/26
GENERATED ON 10/6/20, 12:50 PM
3 OF 6
Fall 102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes In use or changes In structures required
by this code, which are within the scope of the International
Building Code , shall be made In accordance therewith.
Fail 102.4 - Application of building code.
The design and construction of new structures shall comply
with the International Building Code , and any alterations,
additions, changes in use or changes in structures required
by this code, which are within the scope of the International
Building Code , shall be made in accordance therewith.
Fail 304.3.1 - Spontaneous ignition.
OMaterials susceptible to spontaneous ignition, such as oily
rags, shall be stored in a listed disposal container. Contents
of such containers shall be removed and disposed of daily.
Location: Water heater
Comments: Licensed contractor shall obtain permit and Inspection
for water heater Installed without permit.
Additional comments: No permit in system on 1018126
,c., CnwtlACTOO
...
Location: Used cooking oil storage tank
Comments: Licensed electrical contractor shall obtain permit and
inspection for receptacle added without permit.
Additional comments: No permit in system on 1018126
Location: Kitchen
Comments: Provide listed container with self closing lid for disposal
of soiled rags. Rags and towels soiled with fats, oils or grease shall
not be disposed of in the trash.
Additional comments: Has not been ordered yet on 1018126
GENERATED ON 10/8/26, 12:50 PM
4 OF 6
Fail
603.2.2 • Unapproved conditionsOpen electrical terminations.
Open Junction boxes and open -wiring splices shall be
prohibited. Approved covers shall be provided for all switch
and electrical outlet boxes.
Location: Exterior outlets (2) next to Ice Freezer
Comments: Replacing missing weather rated outlet covers.
Additional comments: No progress on 1018128