Loading...
HomeMy WebLinkAboutA TO Z LEARNING CENTER-3243 UNIVERSITY AVINVOICE DATE DUE DATE INVOICE # TOTAL DUE 10/14/2026 11/20/2026 2027-00000188 $100.00 Customer #: 13103 A TO Z LEARNING CENTER 3243 UNIVERSITY AV WATERLOO, IA 50701 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION -3243 UNIVERSITY AV-10/12/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER # BILLING DATE DUE DATE INVOICE # CHARGES 13103 10/14/2026 11/20/2026 2027-00000188 $100.00 Less Prepayment Total Due —> City of Waterloo $0.00 $100.00 Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report A - 2 Learning Center - 3243 University AVE, BLDG 3243 University Ave, Waterloo IA 50701 INSPECTION DETAILS Inspection Date 10/1212026 Lead Inspector BRAD BALDWIN Inspection Type Annual Inspection (1Yr) Other Inspectors N/A MoZ 1-16,1uk:u 425 E.3rd Street tV Inspection Number i I 00 24687 Shift Station Unit N/A N/A NIA SUMMARY OF INSPECTION �45 C 8 Passed codes NEXT STEPS 23 Failed codes N/A cades Please direct questions about your Inspection to: BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 GENERAL NOTES BRAD BALDWIN - 10/13/2026 @ 14:15 Fire drill completed 9/17/26 BRAD BALDWIN - 10/13/2026 @ 14:05 Fire extinguishers due for annual service February 2027 Reinspection Date 11/12/2026 BRAD BALDWIN -10/13/2026 @ 14:03 • If all corrections are made before the scheduled re -inspection date, you can call to set up an earlier re -inspection. Normal operating hours for inspections & re -inspections are Monday - Friday, 9:00 a.m. - 4:00 p.m. *****Re inspection fees may be assessed for subsequent re -inspections. Re - inspection fees start at $100, then $150, and $200 for all subsequent re -inspections. BRAD BALDWIN - 10/13/2026 @ 14:03 • Commercial Fire Inspector - brad.baldwin@waterloo-ia.org - Work: 319-291-4319 (#0) - Cell: 319-230-1224 BRAD BALDWIN-10113/2026 @ 14:03 • $80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Mellissa Fischer CHECKLISTS Date: BRAD BALDWIN 10/1312026 GENERATED ON te/13/2a, 2:17 PM 1 OF 7 Means of Egress Status Code Fall 1032.2 • Reliability. Required exit accesses, exits and exit discharges shall be continuously maintained free from obstructions or Impediments to full instant use In the case of fire or other emergency where the building area served by the means of egress is occupied. An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Emergency Equipment Status Code Fail 1203.2.6 - Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3. The system shall be capable of powering the required Toad for a duration of not less than 90 minutes. Description Location: Duck Room Comments: Remove items in exit path to exterior exit door. Maintain clear exit path at all times. Also, remove obstructions (see photo) In exit path on exterior deck part of exit path from building. Description Location: Duck Room Comments: Repair or replace exit sign and egress lights that failed to illuminate during test GENERATED ON 10/13/26, 2:17 PM 2 OF 7 General Housekeeping Status Code Fail 315.3.1 - Ceiling clearance. Storage shall be maintained 2 feet (610 mm) or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches (457 mm) below sprinkler head deflectors in sprinklered areas of buildings. Exceptions: 1.The 2-foot (610 mm) ceiling clearance is not required for storage along walls In nonsprinklered areas of buildings. 2.The 18-Inch (457 mm) ceiling clearance Is not required for storage along walls in areas of buildings equipped with an automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3. Additional Codes _Lau,_, :ode Fail Fail 603.1- General. Electrical equipment, wiring and systems required by this code or the International Building Code shall be installed, used and maintained in accordance with NFPA 70 and Sections 603.2 through 603.10. 610.1.2 - Maintenance. The lint trap, mechanical and heating components, and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Description Location: Kitchen / storage room Comments: Lower storage within 24" of ceiling. Description Location: Basement - electric room Comments: Remove dehumidifier from plugged to power strip, appliances including motors shall plug directly to an outlet. Also, power strip shall be properly supported to avoid hanging by wires. Location: Clothes dryer vent Comments: Provide documentation of cleaning of dryer vent from appliance to the outside of the building with signature and date. Email documentation to fire inspector. GENERATED ON 10/13/26, 2:17 PM 3 OF 7 Electrical Safety Status Code Fail 603.6 • Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Description Location: Basement - School agers room Comments: Remove extension cord plugged to TV. May replace with properly supported power strip with manual reset for low wattage electronics only. GENERATED ON 10/13/26, 2:17 PM 4 OF 7 Portable Fire Extingusihers Status Cod,, Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10, Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Description Location: Kitchen I storage Comments: Fire extinguisher shall be properly serviced and mounted on wall bracket in required location or spares shall be removed from building. Last record of service in 2023. GENERATED ON /0/13/26, 2:17 PM 5 OF 7 Fail 906.2 - General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies. 2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry -chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met: 2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed. 2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal. 2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is perforated. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10. 3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Location: Office Comments: Annually serviced fire extinguisher shall be hung on wall bracket in required locations, Non -required spares shall be serviced and hung or removed from building GENERATED ON 10/13/26, 2:17 PM 6 OF 7 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number NIA NIA Transaction Number NIA GENERATED ON 10/13/26, 2:17 PM 7 OF 7