Loading...
HomeMy WebLinkAboutCOMMUNITY UNITED CHILD CARE CENTER-3610 ANSBOROUGH AV OF W A P4 INVOICE DATE DUE DATE INVOICE# TOTAL DUE � �� 10/20/2026 11/24/2026 2027-00000200 $100.00 r 0 • •, in II 1!I • Y T 0 44,— 7 f l.)' Customer#: 11638 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable COMMUNITY UNITED CHILD CARE CENTER 715 Mulberry St 3610 ANSBOROUGH AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 3610 ANSBOROUGH AVE- FOR BILLING INQUIRY: (319)291-4323 10/13/26 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11638 10/20/2026 11/24/2026 2027-00000200 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue ;i ` `° Inspection Report 425 E.3rd Street Community United Child Care-3610 Ansborough AVE,BLDG 3610 Ansborough Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 10/13/2026 Annual Inspection(1Yr) I, / -41°0 ,DO 19614 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 42 G 12 ® 26 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspectian Date BRAD BALDWIN 11/1312026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-10/16/2026 @ 07:38 Christmas lighting approved for temporary usage(90 days).Lighting shall be removed after 90 days expires. BRAD BALDWIN-10/1612026 @ 07:37 Extinguishers due annually serviced June 2027 BRAD BALDWIN-10/16/2026 @ 07:37 Clothes dryer cleaning nl+A:tA.nnpM Are,Vi=.lA vg xn i1141339±Eb.11%:u.+N6`W dean flehod Pnm a0aln Cmnkie every snnwM mmae -1 BRAD BALDWIN-10116/2026 @ 07:34 Fire drill completed-10/6/26 GENERATED ON 10/16/26, 8:14 AM 1 OF 6 BRAD BALDWIN-10/16/2026 @ 07:33 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-1011612026 @ 07:33 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#0)-Cell:319-230-1224 BRAD BALDWIN-10/16/2026 @ 07:33 •$100 annual inspection fee SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Amy Junkin Date: BRAD BALDWIN 10116/2026 CHECKLISTS GENERATED ON 10/16/26, 8:14 AM 2 OF 6 Additional Codes Status Code Description Fail 1010.2.1-Unlatching. The unlatching of any door or leaf for Location:2 year old room-Room to bathroom exit hallway egress shall require not require more than one operation Comments:Replace door hardware that currently requires more than motion in a single linear or rotational direction to release all one motion to unlock and unlatch door.No more than a single(1) latching and all locking devices.Exceptions:1.Places of motion is allowed in a required exit door. detention or restraint.2.Where manually operated bolt locks are permitted by Section 1010.2.5.3.Doors with automatic flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4,Item 4 5. Fail 1010.2.1-Unlatching. The unlatching of any door or leaf for Location:3 year old room-Room to bathroom exit hallway egress shall require not require more than one operation Comments:Replace door hardware that currently requires more than motion in a single linear or rotational direction to release all one motion to unlock and unlatch door.No more than a single(1) latching and ail locking devices.Exceptions:1.Places of motion is allowed in a required exit door. detention or restraint.2.Where manually operated bolt locks are permitted by Section 1010.2.5.3.Doors with automatic flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4,Item 4 5. Fail 1010.2.1-Unlatching. The unlatching of any door or leaf for Location:4 year old room-Room to bathroom exit hallway egress shall require not require more than one operation Comments:Replace door hardware that currently requires more than motion in a single linear or rotational direction to release all one motion to unlock and unlatch door.No more than a single(1) latching and all locking devices.Exceptions:1.Places of motion is allowed in a required exit door. detention or restraint.2.Where manually operated bolt locks are permitted by Section 1010.2.5.3.Doors with automatic flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4,Item 4 5. Fail 1010.2.1-Unlatching. OThe unlatching of any door or leaf for Location:5 year old room-Room to bathroom exit hallway egress shall require not require more than one operation Comments:Replace door hardware that currently requires more than motion in a single linear or rotational direction to release all one motion to unlock and unlatch door.No more than a single(1) latching and all locking devices.Exceptions:1.Places of motion is allowed in a required exit door. detention or restraint.2.Where manually operated bolt locks are permitted by Section 1010.2.5.3.Doors with automatic flush bolts as permitted by Section 1010.2.4,Item 3 4.4.Doors from individual dwelling units and sleeping units of Group R occupancies as permitted by Section 1010.2.4,Item 4 5. Fail 807.3-Acceptance criteria and reports. Where required to exhibit improved fire performance, Location:Throughout daycare facility curtains,draperies,fabric hangings and other similar Comments:Provide documentation of all curtains andfor draperies combustible decorative materials suspended from walls or meet proper flame performance criteria.Curtainsfdraperies may be ceilings shall be tested by an approved agency and meet the treated if not currently meeting criteria to comply. flame propagation performance criteria of Test Method 1 or Test Method 2,as appropriate,of NFPA 701 or exhibit a maximum rate of heat release of 100 kW when tested in accordance with NFPA 289,using the 20 kW ignition source. Reports of test results shall be prepared in accordance with the test method used and furnished to the fire code official upon request. GENERATED ON 10/16/26, 8:14 AM 3 OF 6 Emergency Equipment �.tus Cod( Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Green hallway illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress light that failed to illuminate during test Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Gym in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test Fire Service Features :atus Code Description Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:4&5 year old rooms protection system equipment to permit immediate safe Comments:Remove obstructions to fire alarm pull stations,maintain operation and maintenance of such equipment.Storage,trash proper clearance of storage from life safety systems. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Whale room protection system equipment to permit immediate safe Comments:Remove obstructions to fire alarm pull stations,maintain operation and maintenance of such equipment.Storage,trash proper clearance of storage from life safety systems. and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. GENERATED ON 10/16/26, 8:14 AM 4 OF 6 Electrical Safety �aatas cotif Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:FACP room Identified electrical hazards shall be abated.Identified Comments:Replace damaged outlet near electric panel hazardous electrical conditions in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. -11 4 , J' • 4k � I Fire Resistant Construction Maintenance si ais .cd Description Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Boiler room and latch automatically. Comments:Repair or replace fire rated door that failed to self close and latch Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Hallway-Double fire doors and latch automatically. Comments:Repair or replace fire doors failing to self-shut and latch GENERATED ON 10/16/26, 8:14 AM 5 OF 6 ro Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid WA $100.00 Invoice Number Check Number Transaction Number WA NIA NIA GENERATED ON 18/16/26, 8:14 AM - 6 OF 6