Loading...
HomeMy WebLinkAboutSTAPLES-1542 FLAMMANG Of W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 10/20/2026 11/24/2026 2027-00000208 $100.00 • II mitt • .—.�T p *Ss 7VI1N7 Customer#: 4709 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STAPLES 715 Mulberry St PO BOX 9263 WATERLOO, IA 50703 FARMINGHAM, MA 01712 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1542 FLAMMANG DR-10/16/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4709 10/20/2026 11/24/2026 2027-00000208 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. OF W p t.4" INVOICE DATE DUE DATE INVOICE# TOTAL DUE A a 0 08/20/2026 09/25/2026 2027-00000085 $100.00 • •11 ■11 gin II • IF 0 _ ._'`5 7111 BAST [ Customer#: 4709 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STAPLES 715 Mulberry St PO BOX 9263 WATERLOO, IA 50703 FARMINGHAM, MA 01712 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1542 FLAMMANG DR- FOR BILLING INQUIRY: (319)291-4323 08/12/2026 Description Total Price INSPECTION 2,000 HH $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4709 08/20/2026 09/25/2026 2027-00000085 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue i:**41 Inspection Report 425 E. 3rd Street IkailA Staples - 1542 Flammang DR, BLDG 1542 Flammang Dr, Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 10116/2026 Annual Inspection (1Yr) REINSPECTION ) 476 1'1IYDsv 1043-R2 Lead Inspector °"ii Station BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION � 0 e 8 0 9 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org, 3192914319 11120f2026 GENERAL NOTES BRAD BALDWIN - 1011912026 @ 07:41 $100 re-inspection fee for failure to correct all violations. Complete all corrections to avoid fees at following inspections. Per staff on-site: Store closing permanently as of November 10, 2026. BRAD BALDWIN -09114/2026 @ 14:37 • $110 annual inspection fee BRAD BALDWIN -0911412026 @ 14:37 •Commercial Fire Inspector- brad.baldwin@waterloo-ia.org -Work: 319-291-4319 (#0) - Cell: 319-230-1224 BRAD BALDWIN -09/14/2026 @ 14:37 • If all corrections are made before the scheduled re-inspection date, you can call to set up an earlier re-inspection. Normal operating hours for inspections& re-inspections are Monday- Friday, 9:00 a.m. -4:00 p.m. *****Re inspection fees may be assessed for subsequent re-inspections. Re- inspection fees start at$100, then $150, and $200 for all subsequent re-inspections. BRAD BALDWIN -09/14/2026 @ 14:37 Annual fire alarm and sprinkler system inspections due by 9/17/26. Reports of inspections required to be uploaded to Compliance Engine including deficiencies repaired. BRAD BALDWIN -09/14/2026 @ 14:37 Fire extinguishers due annually serviced by September 2026. BRAD BALDWIN -09114/2026 @ 14:37 Corrected on site during 8/12/26 inspection: Removed laminator equipment from extension cord and cord was removed from walkway. Laminator shall plug to a permanent outlet, adding a new outlet requires a licensed electrical contractor to obtain permit and inspection. BRAD BALDWIN -09/14/2026 @ 14:37 Withholding re-inspection fee on 9/14/26 due to progress, complete corrections to avoid fees at following inspections. SIGNATURES GENERATED ON 10/19/26, 7:58 AM 1 OF 6 Contact signature Inspector signature No signature Report completed post inspection General Manager(Brooke)2026 Date: BRAD BALDWIN 10/19/2026 CHECKLISTS GENERATED ON 10/19/26, 7:58 AM 2 OF 6 Reinspection Status Code Description Fail 1013.1-Where required. Exits and exit access doors shall be marked by an approved Location:NW corner-Sales floor exit sign readily visible from any direction of egress travel. Comments:Rotate exit sign to direct path of egress from view of The path of egress travel to exits and within exits shall be western most aisle. marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs.Exit sign placement shall be such that any point in an exit access corridor or exit passageway is within 100 feet(30 480 mm)or the listed viewing distance of the sign,whichever is less,from the nearest visible exit sign. Exceptions:1.Exit signs are not required in rooms or areas that require only one exit or exit access.2.Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the fire code official.3.Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1,R-2 or R-3.4.Exit signs are not required in dayrooms,sleeping rooms or dormitories in occupancies in Group 1-3.5.In occupancies in Groups A-4 and A-5,exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency. Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Exit hallway near manager's officelbreakroom continuously maintained free from obstructions or Comments:Remove all items and storage in hallway,all g y portions of a impediments to full instant use in the case of fire or other required exit path shall remain unobstructed at all times.No storage emergency where the building area served by the means of shall be kept in hallway. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. t 1:',".'d ',„ t.,,,,,,: - - ,Vo.,:, , , ..121, \f.' ,' .7v;t,,1/41 . re 4!t 1 GENERATED ON 10/19/26, 7:58 AM 3 OF 6 Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Backup emergency lighting illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing all egress lighting including repairs completed of any deficiencies to maintain working properly.Document shall state address,date and signature of responsible person.Email document to inspector at brad.baldwin@waterloo-ia.org Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:All exit signage in Section 1013.6.3.The system shall be capable of powering Comments:Provide documentation of testing all exit signs including the required load for a duration of not less than 90 minutes. repairs completed of any deficiencies to maintain working properly. Document shall state address,date and signature of responsible person.Email document to inspector at brad.baldwin@waterloo- ia.org Fail 507.5.5-Clear space around hydrants. A 3-foot(914 mm)clear space shall be maintained around the Location:Rear of building circumference of fire hydrants,except as otherwise required Comments:Clear vegetation obstructing hydrants. or approved. Fail 509.2-Equipment access. Approved access shall be provided and maintained for all fire Location:Back storage area protection system equipment to permit immediate safe Comments:Remove all storage within 3 feet of sprinkler riser operation and maintenance of such equipment.Storage,trash equipment,maintain proper clearances at all times.Suggest marking and other materials or objects shall not be placed or kept in floor where storage shall not be kept to avoid repeat violation. such a manner that would prevent such equipment from being readily accessible. `: I ' t iii a ,1_ 9 iftrimitti Wit, , 4 , , ' _ ,. * __ .,,,&.',z-:::7--.,'„v- ,..*-_, -_ . GENERATED ON 10/19/26, 7:58 AN 4 OF 6 Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall he Location:Middle storage room prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. Comments:Provide knockout plug for opening in box. � B k , 41 "#. Fail 901.4.7.2-Marking on access doors. Access doors for automatic sprinkler system riser rooms and Location:Rear of building-Exterior door near sprinkler riser fire pump rooms shall be labeled with an approved sign.The Comments:Permanent approved signage shall be installed on lettering shall be in contrasting color to the background. exterior side of door indicating"SPRINKLER RISER"or like wording. Letters shall have a minimum height of 2 inches(51 mm)with Laminated paper will not be accepted. a minimum stroke of 318 inch(10 mm). Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Back storage-near sprinkler riser obscured from view.In rooms or areas in which visual Comments:Repair or replace extinguisher signage falling off wall. obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. 1 z,1 Wi,`sy, _ ... :.- i \ 14 't GENERATED ON 1O/19/26, 7:58 AM 5 OF 6 So Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 18/19/26, 7:58 AM 6 OF 6