Loading...
HomeMy WebLinkAboutTHE LOFT-710 JEFFERSON ST OF W A ?. INVOICE DATE DUE DATE INVOICE # TOTAL DUE o 10/20/2026 11/24/2026 2027-00000211 $80.00 • 81 ■ 1 1 • Customer #: 23382 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable THE LOFT 715 Mulberry St 710 JEFFERSON ST #4 WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 710 JEFFERSON ST-10/13/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE # CHARGES 23382 10/20/2026 11/24/2026 2027-00000211 $80.00 Less Prepayment $0.00 Total Due - > $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report �� ) 425 E.3rd Street The Loft-710 Jefferson ST,BLDG 710 Jefferson St-STE Upper Floor,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type 0 Inspection Number 10/1312026 Annual Inspection(1Yr) ,� J�, 18806 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA NIA Other Inspectors N/A SUMMARY OF INSPECTION J44 13 ® 24 Pzs>_d cc,!,- Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 1110612026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-1011912026 @ 15:05 Stage curtains-2026.100%fire retardant polyester FR ?!€PA 701 BRAD BALDWIN-10119/2026 @ 14:49 Christmas lighting approved for temporary(90 days)usage only.Remove lighting after 90 days has expired BRAD BALDWIN-10/19/2026 @ 14:13 Fire extinguishers due annually serviced October 2027 BRAD BALDWIN-10/19/2026 @ 14:13 If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday—Friday,9:00 a.m.—4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- GENERATED ON 10/10/20, 3:1.3 PM 1 OF 6 inspection fees start at$100,then$150,and$200 for all subsequent re-Inspections. BRAD BALDWIN-1011912026 @ 14:13 •Provide corrections to avoid progressive re-inspection tees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-10119/2026 @ 14:12 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(40)-Cell;319-230-1224 BRAD BALDWIN-10/19/2026 @ 14:12 •$80 annual inspection fee SIGNATURES Contact signature Inspector signature No signature } Report completedeelpost stinspection `1 Dana Dzick(2026) Date: BRAD BALDWIN 10119/2026 CHECKLISTS Emergency Equipment c`a:'" Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Front exit-High bay exit sign in Section 1013.6.3.The system shall be capable of powering Comments:Provide document indicating exit sign has been tested the required load for a duration of not less than 90 minutes. and functioning properly Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Near bar in Section 1013.6.3.The system shall be capable of powering Comments:Remove Halloween decorations draped over exit sign the required load for a duration of not less than 90 minutes. Fire Sprinkler System Status Co:: Description Fail 4.9-Support of nonsprinkler system components Sprinkler system components shall not be used to support Location:Above"Sam Adam's"mirror non-sprinkler system components unless expressly permitted Comments:Remove HDMI cord hanging sprinkler by NFPA 13. 9 9 on p piping Fail 4.9-Support of nonsprinkler system components L 1 Sprinkler system components shall not be used to support Location:Near stage non-sprinkler system components unless expressly permitted Comments:Remove speaker wire being supported by sprinkler by NFPA 13. piping. GENERATED ON 10/1G/26, 3:23 PM 2 of 6 Additional Codes Status Code Description Fail 5303.5.3-Securing compressed gas containers,cylinders and tanks. Location:Bar Compressed gas containers,cylinders and tanks shall be Comments:Secure tanks to avoid tip-over hazard. secured to prevent falling caused by contact,vibration or seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Fail 907.8.1-Maintenance required. Where required for compliance with the provisions of this Location:Fire alarm code,devices,equipment,systems,conditions, Comments:Deficiency(see attachment)shall be corrected including arrangements,levels of protection or other features shall contractors repair report to be uploaded to Compliance Engine. thereafter be continuously maintained in accordance with applicable NFPA requirements or as directed by the fire code official. GENERATED ON 10/19/26, 3:13 PM 3 OF 6 Electrical Safety Std'-us Code Description Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:"Boulevard Brewing"sign connected to a permanently installed receptacle.Exceptions: Comments:Power strip above sign"daisy chained"shall be removed 1.Where approved for use in a Group A occupancy or Ina to be plugged directly to a permanent outlet meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Stage connected to a permanently installed receptacle.Exceptions: Comments:Remove power strip plugged to multi-plug adapter, 1.Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. c 0 v / ;-,'' . may. *I z + ; rifry � 2 t i ''";fi 'Eye, 2 4 CS"_ f 1: t 'S�s � rsba t Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Gambler games ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip above games to avoid to environmental or physical damage. hanging by wires GENERATED ON 10/10/26, 3:13 PM 4 OF 6 Fall 603.6-Extension cords. 0 Extension cords and flexible cordsshall not be a substitute Location:Back closet for permanent wiring and shall be listed and labeled In Comments:Remove extension cords. accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical Impact.Extension cords shall be used only with portable appliances.Extension cords marked for Indoor use shall not be used outdoors. Fail 603.6•Extension cords. 0 Extension cords and flexible cordsshall not be a substitute Location:Near stage for permanent wiring and shall be listed and labeled in Comments:Remove black extension cord accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Near"Sam Adam's"neon sign for permanent wiring and shall be listed and labeled in Comments:Remove extension cord accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Near sound board for permanent wiring and shall be listed and labeled in Comments:Remove extension cords(2) accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 16/10/26, 3:13 PM 5 OF 6 , Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 16/10/26, 3:13 PM 6 OF 6